Fractional CO2 laser MED-X with RF module
-
120 600 AED
Cashback 0% -
- Brand: Alvi Prague
- Product Code: CO2 laser MED-X + RF
Fractional CO2 laser MED-X with RF module
MED-X Laser CO2 Fractional Laser with RF Module: Effective Rejuvenation Without Surgery
The MED-X Laser CO2 fractional laser with RF module is a groundbreaking device that delivers surgical-free rejuvenation. This innovative equipment leverages laser ablation or photothermolysis, making it suitable for applications in cosmetology, dermatology, and gynecology. The device complies with all EU safety standards.
What is a Fractional Laser and How Does It Work?
The fractional laser employs an ablative method. When in contact with the skin, it creates a fractional effect by generating a light beam with a wavelength of 10.6 microns. This beam produces "microthermal treatment zones" (MTZ) with controlled width, depth, and density.
Surrounding these zones are intact areas of viable epidermis and dermis, which aid in rapid recovery. The laser damages only specific areas of the skin, typically covering 15-35% of the total treated surface.
- Vaporization depth: Ranges from 100 to 2000 micrometers, depending on the laser’s energy settings.
- Energy control: Higher energy increases penetration depth, enhancing the treatment’s effectiveness.
What Effect Can Be Achieved with a Fractional Laser?
Using the CO2 fractional laser, practitioners can perform:
- Laser resurfacing
- Removal of wrinkles, stretch marks, scars, and uneven skin texture
- Removal of age-related pigmentation
- Elimination of superficial tumors such as papillomas, condylomas, and warts
- Rejuvenation of the skin and mucous membranes of female reproductive organs
- Therapy and prevention of gynecological conditions
The MED-X Laser CO2 fractional laser offers clients quick and safe solutions for cosmetic and intimate rejuvenation.

Why Fractional Laser and CO2 with RF Module?
The fractional laser targets tissues selectively, vaporizing some areas while leaving others untouched. This selective approach minimizes healing time to just a few days.
- CO2 principle: Utilizes carbon dioxide as an active medium.
- Precision: Includes a diode laser targeting device for accurate light spot movement.
- Efficient delivery: The radiation is transmitted via a flexible seven-branch optical waveguide.

Advantages of the RF Module
The MED-X Laser CO2 fractional laser uses a radio frequency module (RF tube) instead of a traditional glass gas discharge tube. Key benefits include:
- Reliable service life: RF tubes offer unlimited operational durability.
- Accuracy: Stable laser radiation ensures consistent ablation zone size and depth.
- Ease of maintenance: Air-cooled RF tubes eliminate the need for regular water changes.
- Robust design: RF modules are highly resistant to damage during transportation.

Prolonged Effect
The device induces controlled aseptic inflammation, lasting several days. This stimulates active tissue proliferation and collagen synthesis, resulting in visible skin rejuvenation and tightening. New structural elements of the dermis and epidermis form, delivering long-lasting improvements.
Indications and Contraindications
Indications:
- Warts and recurrent condylomas
- Sebaceous gland hyperplasia
- Keloid and atrophic scars
- Stretch marks
- Xanthelasma
- Hemangiomas
- Pigmentation issues

Contraindications:
- Malignant neoplasms
- Collagenosis
- Fever of unclear etiology
- Thyroid disorders
- HIV and hepatitis C
- Bacterial or viral skin diseases
- Somatic diseases in decompensated stages
- Recent medium or deep chemical dermabrasion (within six months)
- Pregnancy and lactation

Possible Side Effects
While minimally invasive, laser ablation can cause:
- Prolonged tissue swelling
- Pain in the treated area
- Infection due to poor hygiene
Protective goggles for both the operator and client are mandatory during sessions.

Protocol for Using a Fractional CO2 Laser
- Medical History: Review client’s medical records and discuss expectations.
- Skin Cleansing: Use an ultrasonic scrubber for surface cleaning.
- Disinfection: Treat the area with chlorhexidine.
- Anesthesia: Apply cooling or lidocaine cream for pain management.
- Post-Exposure Care: Treat the area with chlorhexidine and apply healing cream.
Treatment duration depends on the area, ranging up to 60 minutes. For minor defects, a single pass may suffice. Comprehensive procedures like scar resurfacing typically require three sessions with recovery periods of 7-14 days.

Why Choose Us?
- Adherence to national health and beauty standards.
- User-friendly interface for quick mastery.
- Minimal recovery period with no residual marks.
- Free training at your location.
- 18-month warranty with post-warranty support and upgrades.
The MED-X Laser CO2 fractional laser is a reliable, effective solution for professionals seeking to deliver exceptional results while ensuring client safety and comfort.

|
Laser type |
Fractional CO2 |
|
Energy |
2.1 mJ до 400 mJ |
|
Pump lamp power |
40 W |
|
Pulse length |
0.1 - 10 ms |
|
Pulse frequency |
0.1-10 Hz |
|
Laser wavelenght |
10600 nm |
|
Spot size |
0.02 - 0.05 mm2 |
|
Warranty operation time |
18 months |
|
Scanned dots |
400 max. |
|
Interval between dots |
0.1 - 2.6 mm (adjustable) |
|
Scanned image |
rectangle, ellipse, circle, line, square, triangle, hexagon |
|
Guide beam |
Semiconductor laser with a wavelength of 635nm, power up to 5 mW |
|
Beam transmission system |
7-joint optical waveguide |
|
Cooling system |
air cooling |
|
Network parameters |
|
|
Power supply |
220-240 V / 50 Hz |
|
Power input |
650 W or less depending on the selected intensity and operating mode |
|
Safety |
|
|
Protection class |
IP20 |
|
Dimensions |
|
|
Net dimensions (H*L*W) |
1677*488*398 mm |
|
Gross dimensions |
1052*620*644 mm |
|
Net weight |
46.7 kg |
|
Gross weight |
74.1 kg |
|
Waveguide weight |
4.5 kg |
|
1. |
Fractional laser MED-X Laser CO2 |
1 pc. |
|
2. |
Key to turn on/off the device |
2 pcs. |
|
3. |
Power cord |
1 pc. |
|
4. |
Pedal with connection wire |
1 pc. |
|
5. |
Optical waveguide in a special protective case |
1 pc. |
|
6. |
Laser scanner-emitter |
1 pc. |
|
7. |
Laser focusing lens |
1 pc. |
|
8. |
Nozzles for laser emitter |
1 pc. |
|
9. |
Cone tip for vaginal nozzle type A |
1 pc. |
|
10. |
Beveled tip for vaginal handpiece type A |
1 pc. |
|
11. |
Handpiece with stop for laser scalpel handpiece |
1 pc. |
|
12. |
Handpiece with short reach for laser scalpel handpiece |
1 pc. |
|
13. |
Handpiece with a long treatment area for laser scalpel handpiece |
1 pc. |
|
14. |
Protective goggles for a beautician |
1 pc. |
|
15. |
Protective goggles for the patient |
1 pc. |
|
16. |
User manual |
1 pc. |
|
17. |
Transportation package |
2 pcs. |
|
Consumables |
||
|
18. |
Fuses |
2 pcs. |
Related Products
Vascular laser DLS-980
The vascular laser DLS-980 is a modern, professional device designed for use in beauty rooms, clinic..
36 600 AED
Professional IPL machine IP-200 Light Pro Duo
IP-200 Light Pro Duo: Unlimited Possibilities and High Efficiency The IP-200 Light Pro Duo is a p..
11 446 AED